控制器 - 机器安全

结果:
387
Manufacturer
Series
Safety Outputs and Type
Features
Contact Rating @ Voltage
Number of Inputs and Type
Voltage - Supply
Auxiliary Outputs and Type
Safety Category
Ingress Protection
Controller Type
Operating Temperature
Termination Style
Mounting Type
结果387
选择
图片产品详情单价可用性ECAD 模型FeaturesIngress ProtectionOperating TemperatureMounting TypeVoltage - SupplyContact Rating @ VoltageTermination StyleNumber of Inputs and TypeController TypeSafety Outputs and TypeAuxiliary Outputs and TypeSafety CategorySeries
XPSMCMEN0200HTG
SAFESPEED 2 IN HTL ENC+2 PROX SP
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
IP20
-10°C ~ 55°C
DIN Rail
24VDC
-
Spring Terminal
-
Expansion Module
-
-
Category 4, PLe, SIL3
Modicon MCM
MC6AC-1114
CONTROL SAFETY MAT 100-240V
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
IP65 - Dust Tight, Water Resistant
0°C ~ 55°C
Chassis Mount
100 ~ 240VAC, 24VDC
7A @ 230VAC
Circular
6 - Digital
Safety Mat
Relay (3)
Relay (2)
Category 3
MC6AC-1112
CONTROL SAFETY MAT 100-240V
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
IP65 - Dust Tight, Water Resistant
0°C ~ 55°C
Chassis Mount
100 ~ 240VAC, 24VDC
7A @ 230VAC
Circular
6 - Digital
Safety Mat
Relay (3)
Relay (2)
Category 3
MC6AC-1110
CONTROL SAFETY MAT 100-240V
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
IP65 - Dust Tight, Water Resistant
0°C ~ 55°C
Chassis Mount
100 ~ 240VAC, 24VDC
7A @ 230VAC
Circular, Screw Terminal
6 - Digital
Safety Mat
Relay (3)
Relay (2)
Category 3
MC6AC-1014
CONTROL SAFETY MAT 100-240V
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
IP65 - Dust Tight, Water Resistant
0°C ~ 55°C
Chassis Mount
100 ~ 240VAC, 24VDC
7A @ 230VAC
Circular
6 - Digital
Safety Mat
Relay (3)
Relay (2)
Category 3
MC6AC-0113
CONTROL SAFETY MAT 100-240V
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
IP65 - Dust Tight, Water Resistant
0°C ~ 55°C
Chassis Mount
100 ~ 240VAC, 24VDC
7A @ 230VAC
Circular, Screw Terminal
6 - Digital
Safety Mat
Relay (3)
Relay (2)
Category 3
MC6AC-0015
CONTROL SAFETY MAT 100-240V
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
IP65 - Dust Tight, Water Resistant
0°C ~ 55°C
Chassis Mount
100 ~ 240VAC, 24VDC
7A @ 230VAC
Circular, Screw Terminal
6 - Digital
Safety Mat
Relay (3)
Relay (2)
Category 3
MC6AC-0011
CONTROL SAFETY MAT 100-240V
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
IP65 - Dust Tight, Water Resistant
0°C ~ 55°C
Chassis Mount
100 ~ 240VAC, 24VDC
7A @ 230VAC
Circular, Screw Terminal
6 - Digital
Safety Mat
Relay (3)
Relay (2)
Category 3
MC6AC-0010
CONTROL SAFETY MAT 100-240V
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
IP65 - Dust Tight, Water Resistant
0°C ~ 55°C
Chassis Mount
100 ~ 240VAC, 24VDC
7A @ 230VAC
Screw Terminal
6 - Digital
Safety Mat
Relay (3)
Relay (2)
Category 3
MC4-1106
CONTROL SAFETY MAT 24V
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
IP65 - Dust Tight, Water Resistant
0°C ~ 55°C
Chassis Mount
24VDC
6A @ 230VAC
Circular
6 - Digital
Safety Mat
Relay (4)
-
Category 3
TM3SAC5RG
SAFETY MODULE, MODICON TM3 SAFET
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
IP20
-10°C ~ 55°C
DIN Rail
24VDC
-
Spring Terminal
-
General Purpose
Relay (3)
-
Category 3
Modicon TM3
XPSMCMC10804G
CONTROLLER WITH 8 INPUTS 4 OUTPU
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
IP20
-10°C ~ 55°C
DIN Rail
24VDC
-
Spring Terminal
-
Expansion Module
-
-
-
Modicon
XPSMCMDO0004SG
4 DIGITAL OUTPUT EXPANSION MODUL
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
IP20
-10°C ~ 55°C
DIN Rail
24VDC
-
Spring Terminal
-
Expansion Module
-
-
-
Modicon
XPSMCMDO0016C1G
16 DIGITAL OUTPUT PLC, SIL1 EXPA
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
IP20
-10°C ~ 55°C
DIN Rail
24VDC
-
Spring Terminal
-
Expansion Module
-
-
-
Modicon
XPSUAT33A3AC
SAFETY MODULE, HARMONY SAFETY AU
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
IP20
-25°C ~ 85°C
DIN Rail
48 ~ 240VAC/DC
-
Screw Terminal
3 - Digital
General Purpose
Relay (4)
-
Category 4
Harmony XPS
XPSUAK12AP
SAFETY MODULE, HARMONY SAFETY AU
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 55°C
DIN Rail
24VAC/DC
-
Screw Terminal
-
Safety Edge
-
-
-
Harmony XPS
XPSABV11330C
MODULE XPSABV - STOP AND SWITCH
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
IP20
-25°C ~ 55°C
DIN Rail
24VAC/DC
-
Screw Terminal
-
General Purpose
Relay (2)
-
Category 4
Harmony XPS
XPSABV1133P
MODULE XPSABV - STOP AND SWITCH
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
IP20
-25°C ~ 55°C
DIN Rail
24VAC/DC
-
Screw Terminal
-
General Purpose
Relay
-
Category 3
Harmony XPS
XPSABV1133C
MODULE XPSABV - STOP AND SWITCH
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
-
IP20
-25°C ~ 55°C
DIN Rail
24VAC/DC
-
Screw Terminal
-
General Purpose
Relay (3)
-
Category 4
Harmony XPS
XPSUVN31AP
ZERO SPEED MONITORING 48-240 V S
联系我们
数量
联系我们
PCB Symbol, Footprint & 3D Model
Delay Time 0.5 ~ 60sec
IP20
-25°C ~ 55°C
DIN Rail
48 ~ 240VAC/DC
5A @ 48~240VAC/DC
Screw Terminal
-
General Purpose
Relay (1), Solid State (2)
-
Category 3, PLe, SIL3
-

控制器 - 机器安全

机器安全控制器在确保工业机械和设备安全方面起着关键作用。它们用于集成和监控各种工业安全设备,如紧急停止装置、安全门、光栅、磁性互锁或安全边缘、垫子和光束等。 这些控制器可以组成一个简单或复杂的设备系统,通过软件和硬件在一个独立的专用系统中进行通信。或者它们可能被集成到正常的机器控制系统中。 机器安全控制器提供了一种可靠的手段来检测和响应机械或设备内的不安全条件。它们可以检测任何潜在的危险,并触发适当的安全响应机制,例如紧急停止或关机。 使用机器安全控制器的主要好处之一是它们提供了所有安全设备的集中控制点。这种集中控制有助于确保所有安全设备正确地协同工作,并及时检测和解决任何问题。 机器安全控制器还提供了灵活性和定制选项。它们可以配置以满足不同类型机械和设备的特定安全需求。这个功能使用户能够为其特定的应用程序定制其安全系统,以满足其独特的要求。 总之,机器安全控制器在确保工业机械和设备安全方面起着关键作用。它们可以集成和监控各种安全设备,检测潜在的危险并触发适当的安全响应机制。这些控制器提供集中控制、灵活性和定制选项,使它们高度可靠且适应不同的应用需求。